One sub, one schedule, one contract. ACG handles Division 08 from bid to closeout — storefront, curtainwall, window wall, impact glazing, multi-slide doors, fire-rated glazing, automatic entrances, and hardware. 48-hour scope turnaround. $3M/$6M bonded. Zero OSHA recordables.
Send drawings Monday — you have a detailed Division 08 scope letter Wednesday. Not a phone-call quote. Not an allowance-stuffed budget number. A line-item scope with system recommendations, named manufacturer per opening category, NOA / Florida Product Approval cross-references, and an explicit exclusion list.
ESWindows aluminum storefront, ESWindows-class clear-anodized and dark-bronze systems for retail, restaurant, office, and clubhouse work.
Stick-built and unitized curtainwall up to 5 stories. Pressure-equalized, captured and structural-silicone glazed.
Slab-to-slab window wall for hospitality, multifamily, and Class A office. Integrated with shadow boxes and spandrel detailing.
NOA-certified impact systems for Miami-Dade, Broward, and statewide HVHZ. TAS 201 / 202 / 203 compliant.
Authorized commercial installer for Euro-Wall folding, sliding, and pivot systems. Restaurant, residential, and clubhouse openings up to 30+ ft.
TGP Pilkington Pyrostop and Pyrobel fire-rated glazing assemblies, 20-180 minute ratings, NFPA 80 compliant.
Allegion-certified automatic entrance hardware integration — slide, swing, balanced. ADA-compliant configuration.
Coordinated Division 08 packages including HM frames, wood and metal doors, hardware sets, and full submittal coordination.
| Item | Status |
|---|---|
| Florida License | CGC #1531993 (active) — verifiable on myfloridalicense.com |
| Bonding Capacity | $3M single project / $6M aggregate (Treasury-listed surety) |
| General Liability | $1M / $2M per occurrence / aggregate |
| Excess / Umbrella | $5M (scalable to $10M for projects $5M+) |
| Workers Compensation | Statutory Florida coverage |
| Auto Liability | $1M combined single limit |
| EMR | At or below 1.0 baseline; current letter on request |
| OSHA Record | 0 recordables across 350+ projects |
| OSHA Training | OSHA 30 (PM + super), OSHA 10 (installers) |
| ISNetworld | Active and current |
| Avetta | Active and current |
| WBE / SBE | Women's Business Enterprise + Small Business Enterprise certified |
| NAICS | 238150 Glass and Glazing Contractors |
Full prequalification packet (AIA A305 format) on request — 24-hour turnaround. See also the general prequalification reference ACG uses with GCs.
ACG holds direct manufacturer certification with six commercial systems suppliers. These are the only systems that appear in ACG's scope letters. Approved-equal substitution is handled through formal RFI and submittal — never quietly swapped on the field.
Three Florida offices mean a named PM on-site for projects from the Keys to the Panhandle without long-haul mobilization. No other Florida commercial glazing sub operates a multi-office footprint of this kind.
48 hours from receipt of complete drawings. Detailed scope letter with named systems, NOA references, and exclusions.
$3M single project, $6M aggregate, Treasury-listed surety. Bond letters dated within 90 days on request.
Yes, both — active and current. Equivalent procurement platforms (Browz, Veriforce) handled on request.
Zero recordables across 350+ projects. EMR and OSHA 300 logs provided during prequalification.
ESWindows, Euro-Wall, PGT, Allegion, TGP, Slimpact, Aldora. Seven only.
Primary market Florida statewide. Nashville office Q3 2026 for Southeast coverage. Tennessee work uses IBC / IECC / ASHRAE 90.1 specs — not HVHZ.
Have a Florida commercial project with Division 08 scope to award? Send the drawings — a complete scope letter returns in 48 hours.
Send Bid Drawings